Boiler Feed Systems
One of the early applications for regenerative turbine
pumps is in boiler feed systems. In a boiler feed system, the pump supplies
make-up water to the boiler as the boiler water is turned into steam. Steam
boilers operate under pressure, so the pump must develop enough pressure
to overcome the boiler pressure as well as losses due to friction from piping
and check valves. Because of their high pressure pumping characteristic
and their ability to pump water at temperatures close to boiling (low NPSH
requirement) MTH regenerative turbines are very well suited to this application.
MTH services boilers in a variety of sizes; from small units supplying steam
for local drycleaners, to larger systems making steam for industrial processes
and commercial heating systems. MTH can provide regenerative turbine feedwater
pumps for boilers ranging in size from 10KW to 800HP, and operating pressures
to 1000 psi. We are standard equipment on many well known boiler manufacturer's
systems. Regenerative turbine pumps are desirable for on/off water supply, as opposed to continuous feed make-up. A centrifugal pump used in conjunction with a regulating valve is the typical arrangement utilized when continuous operation is required. Please see our low cost stainless steel C41/C51/C61 Series Centrifugal products for continuous feed make-up systems. MTH also offers low cost stainless steel versions of our regenerative turbine products that feature stainless steel casings and corrosion resistant nickel silver impellers that far exceed the life expectancy of bronze fitted iron units. Please contact the factory and ask about our 7CT7MTH unit which is part of our MTH CT Series line, as well as our MTH CR and MTH CS Series lines. Boiler Feed Selection Guide
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MTHPumps.com Home, Find
a Pump Type, Find Your Application,
Standard Products, How
to Buy Our Pumps, |